Why the "Temperature Setting" Tab of OCX only able to specify one channel to actually read from?
Solution:
The "General" setting is suitable for all the AI device, and, the "Temperature" setting is designed for Daughter board. As you know we should assign one channel for one daughter board, so you get such property setup form with this AI control. As to your application, you just need to adjust those general setting properly. Don't care about the "Temperature" setting when you using the ADAM series products. Moreover, due to "General Setting" tab just show you the number of their property, I think it's not convenience to identity those properties in this tab. It's recommended to adjust those general properties in the Porperties-DAQAI1 window or in your program. Please refer to the attached file to see the window. Besides, please notice that the conversion number should be the multiple of the scan channel number, and all the 8 channel must be enable before launch this example. And please kindly install ADAM-4018 via "Device Installation" program and launch the VB example "AITester" to see how the OCX work.
Download File Release Date Download Site
AI_OCX.doc (KM-MHUG-4CZ7H5) 07-26-2000