Doc. # 1-0002865
Date Updated 07-15-2004 Date Created 07-27-2000
Document Type Knowledge Base Related OS
Related Product PCI-1760/ PCI-1760U/ PCLS-NI
Why the PCI-1760 can not work with the LabVIEW driver?
Solution:
Firstly, to work with PCI-1760, you need to install the 32-bit DLL driver higher than V1.10. Secondly, in the standard example, the program continually polls the PCI-1760 in high speed and that is too fast for the relay board PCI-1760 to respond. If we can prolong the polling period and the PCI-1760 can work normally. After testing, we have found that the PCI-1760 can work with Labview driver if we make some modification to the example. We can do that by simply add time-delay into the while loop, just like the following picture.
Download File Release Date Download Site
PCI-1760.bmp (0) 11-24-2000
  1. Primary
  2. Secondary