How to get a 4 to 20 mA current output from PCL-727 while integrated with ADAM-3014? | |||
---|---|---|---|
Solution:
Please refer to the attached file for the detail information.
We've done the 3 ways of connecting with ADAM-3014, add adjust the CURRENT OUTPUT via DOS program TESTPROG.EXE for test. All the combination work properly. Don't forget to add the external DC power supply for this CURRENT OUTPUT application.
|
|||
Download File | Release Date | Download Site | |
727.ppt (KM-MHUG-4JZ4X4) | 07-26-2000 |