Doc. # 1-117034346
Date Updated 05-22-2007 Date Created 08-08-2006
Document Type Knowledge Base Related OS
Related Product USB-4711/ USB-4716/ USB-4718
WaveScan show some error message and can not run on my PC.
Solution:
[Description] After installing WaveScan under WinXP and execute it, it shows” Selected collating sequence not supported by the operating system.” What’s the problem? [Solution] USB modules we support so far are only USB-4711, USB-4716 and USB-4718. Please make sure your modules are one of these. As for error message “Selected collating sequence not supported by the operation system”, user can check by following points: 1. It may be the language support problem, please use platform with multi-language package. 2. Have you ever try to open the stored data in ACCESS? If so, maybe it causes the problem. (1) Open the data in ACCESS (2) Click “Tools”, select “General” and you can find “New Data Sort Order” option frame. (3) Select “General” in “New Data Sort Order” (4) By above steps, you may now be able to use the module without error message. 3. Please make sure you’re using DAO with version 3.6 or above. 4. The Office 2000 ACCESS needs at least Jet 4.0 engine