Doc. # 1-00000285 | |||
---|---|---|---|
Date Updated | 10-26-2018 | Date Created | 09-12-2017 |
Document Type | Knowledge Base | Related OS | |
Related Product | ESP211/ ESP211-232/ ESP211-485 |
How can I reset the ESP211 Series to Factory Default? | |||
---|---|---|---|
Solution:
The Manual states that the reset button should take the unit back to factory defaults. It does not.
Holding the Reset button for longer than 5 sec does not do anything. It is supposed to have the ready LED do a fast blink. It does not.
Please see the following article for factory reset procedure options:
Start on page 7. (ESP211 API Spec Attached)
Except from procedure:
Reset the IP Serial Server
As to reset, similar to searching, create a socket and turn on broadcast mode for this socket with UDP port 6669 then send a command message in format like “cmd_msg” defined in 1.3.The following is an example
to set cmd_msg.
Manager → IP Serial Server
pni serialno mac_addr command ending
IPS Administrator Server’s serial number Server’s mac reset '\0'
(format size:59 bytes, cmd_msg+ '\0')
|
|||
Download File | Release Date | Download Site | |
ESP211_API_Spec_V1.0.0.pdf (ESP211 API Spec) | 10-17-2017 |