Doc. # 1-00000660 | |||
---|---|---|---|
Date Updated | 10-26-2018 | Date Created | 09-12-2017 |
Document Type | Knowledge Base | Related OS | |
Related Product | ERT310/ ERT311/ ERT312/ RT3G-300/ RT3G-300-W/ RT3G-302/ RT3G-310/ RT3G-310-W/ RT3G-311/ RT3G-320-W/ RT3G-322/ RT3G-324/ RT3G-330 |
Spectre Router Binary Inputs and Outputs | |||
---|---|---|---|
Solution:
Binary Inputs The binary input is sampled 8x per second with a sampling period of 1/64 seconds. The active level for each binary input may be set to either a logic 0 or logic 1. The inputs may be configured to generate an alarm when they become active. Binary Outputs The Binary Outputs on the Spectre Routers are sinking. The output transistor is rated at 100mA and 30VDC.
|
|||