Doc. # 1-41045473 | |||
---|---|---|---|
Date Updated | 07-25-2012 | Date Created | 09-22-2004 |
Document Type | Knowledge Base | Related OS | |
Related Product | PCI-1760/ PCI-1761/ PCI-1762/ PCL-725/ PCL-735/ PCM-3725 |
User's note of switching a inductive load | |||
---|---|---|---|
Solution:
It is caused by anti voltage. It coccurs when the relay switch a inductive load. And its amplitude(V) is relative to the induction coil(L), current variation(di) and time(dt). Formula V = -Ldi/dt.
For example, if the load is a relay-OMRON MY24NJ, its current(i)=36.9mA, inductance(L) =5.72H.operation time(t)=4ms Then, the formula is V=-Ldi/dt and get the anti voltage V= -5.72 * 36.9m/4m = -52.75V. Due to the switch time will be faster than operation time, the actual value measuring by instrument is up to -320V.
It will be over reply's specification. To solve this issue, user can add a diode in parallel to discharge this potential.people call it as freewheel diode.
|